Innovation, excellent and reliability are the core values of our firm. These principles today more than ever form the basis of our success as an internationally active mid-size corporation for Radiation Safety Glasses, Xray Voltage, High Voltage Generator Module, Our products have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!
China wholesale Medical X Ray Tube Suppliers - Medical X-ray collimator Automatic x-ray collimator RF202 – Sailray Detail:

Max Voltage 150KV
Maximum X-ray field  coverage  range 430mm×430mm (SID=100cm)
The average brightness of the light field >160 lux
Edge contrast ratio >4:1
Power supply requirement of projection lamp 24V AC/150W
Bright  X-ray  field  duration  for  Once 30S
Distance from Focal Spot of X-ray tube to the mount plane of collimator  SID  (mm)(optional) 60
Filtration(Inherent) 75kV 1mmAl
Filtration(Additional) The outer optional
Control  method Electric/ Manual
Drive motor Stepper Motor
Motor Control TTL  Level signals
Position detection Potentiometer
Input power AC24V/DC24V
(SID)Measuring tape optional
Center laser instructions optional
Dimension(mm)(W×L×H) 185×230×145
Weight(Kg) 7.2

X-ray leakage: <1mGy/h (150kV, 4mA)
The distance from the focus of the X-ray tube to the beam limiter mounting surface: 60mm (can be adjusted according to different tubes)
Maximum irradiation field: 43cmX43cm (SID=1m)
Minimum irradiation field: <5cmX5cm (SID=1m)
 Visible light field brightness: >140lux (SID=1m)
Light field consistency: <2%@SID
Inherent filtration: 1mmAl/75kV
Light field power input: 24VAC/50W or DC24V/1A
 Electrical control power input: 24VDC/2A
CAN bus protocol: CAN2.0A
 Dimensions: 186mm×230mm×145mm (length×width×height)
Weight: 7.2kg

Optional:
External additional filter
Special electrical interface
Special tube ball interface

This x-ray collimator is suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment


Product detail pictures:

China wholesale Medical X Ray Tube Suppliers - Medical X-ray collimator Automatic x-ray collimator RF202 – Sailray detail pictures


Related Product Guide:

abide by the contract, conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China wholesale Medical X Ray Tube Suppliers - Medical X-ray collimator Automatic x-ray collimator RF202 – Sailray , The product will supply to all over the world, such as: Hungary, Bolivia, Nicaragua, We have been persisting in the business essence Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying goods and service. Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Marcie Green from Canada - 2018.12.11 11:26
    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Priscilla from Accra - 2018.09.21 11:44
    Write your message here and send it to us