Medical X-ray collimator

Medical X-ray collimator

  • Medical X-ray collimator Automatic x-ray collimator RF202

    Medical X-ray collimator Automatic x-ray collimator RF202

    Features
    Suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    High reliability and high cost performance
    Using a single layer and two sets of lead leaves and a special internal protective structure to shield X-rays
    The adjustment of the irradiation field is electric, the movement of the lead leaf is driven by a stepping motor, and the irradiation field is continuously adjustable
     Control the beam limiter through CAN bus communication or switch level, or manually control the beam limiter in front of you, and the LCD screen displays the status and parameters of the beam limiter
    The visible light field adopts LED bulbs with higher brightness
    The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
    Convenient and reliable mechanical connection with X-ray tube, easy to adjust

  • Medical X-ray Collimator Automatic X-ray Collimator SR305

    Medical X-ray Collimator Automatic X-ray Collimator SR305

    Suitable for common X-ray diagnostic equipment with tube voltage of 150kV
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    Small size
    High reliability and high cost performance
    Using three layers and two sets of lead leaves and a special internal protective structure to shield X-rays
    The adjustment of the irradiation field is manual, and the irradiation field is continuously adjustable
    The visible light field adopts high-brightness LED bulbs
    The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
    Convenient and reliable mechanical connection with X-ray tube, easy to adjust

  • Medical X-ray Collimator Manual X-ray beam limitter SR302

    Medical X-ray Collimator Manual X-ray beam limitter SR302

    Suitable for common X-ray diagnostic equipment with tube voltage of 150kV
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    Small size
    High reliability and high cost performance
    Using double layers and two sets of lead leaves and a special internal protective structure to shield X-rays
    The adjustment of the irradiation field is manual, and the irradiation field is continuously adjustable
    The visible light field adopts high-brightness LED bulbs
    The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
    Convenient and reliable mechanical connection with X-ray tube, easy to adjust

  • Medical X-ray Collimator Automatic X-ray Collimator 34 SRF202AF

    Medical X-ray Collimator Automatic X-ray Collimator 34 SRF202AF

    Type: SRF202AF
    Applicable for C ARM
    Maximum X-ray field coverage range: 440mm×440mm
    Max Voltage: 150KV
    SID: 60mm

  • Medical X-ray Collimator Automatic X-ray Collimator SR301

    Medical X-ray Collimator Automatic X-ray Collimator SR301

    Features
    Suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    High reliability and high cost performance
     Double layers and two sets of lead leaves and a special internal protective structure are used to shield X-rays. The top lead leaves can enter the window of the X-ray tube, which can shield the stray scattered rays more effectively.
    The adjustment of the irradiation field is manual, continuously adjustable
    The visible light field adopts high-brightness LED bulbs
    The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
    Convenient and reliable mechanical connection with X-ray tube, easy to adjust

  • Medical X-ray Collimator Manual X-ray Collimator SR103

    Medical X-ray Collimator Manual X-ray Collimator SR103

    Features
    Suitable for mobile or portable X-ray diagnostic equipment with a tube voltage of 120kV
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    Small size
    High reliability and high cost performance
    Using a single layer and two sets of lead leaves and a special internal protective structure to shield X-rays
    The adjustment of the irradiation field is manual, and the irradiation field is continuously adjustable
    The visible light field adopts high-brightness LED bulbs
    Convenient and reliable mechanical connection with X-ray tube, easy to adjust

  • Medical X-ray Collimator Manual X-ray beam limitter SR202

    Medical X-ray Collimator Manual X-ray beam limitter SR202

    Features
    Compatible with X-ray diagnostic equipment using 150kV tube voltage, including DR digital systems and conventional systems
     The X-ray irradiation field is rectangular
    Conform to relevant national and industry standards
    Small size
    High reliability and high cost performance
    Uses a single layer, two sets of lead leaves and a specialized internal protection design to block X-rays.
    The adjustment of the irradiation field is manual, continuously adjustable
    The visible light field adopts LED bulbs
    A built-in delay circuit automatically turns off the lamp 30 seconds after activation, and a manual option to turn off the light during operation is also available. These features are designed to extend the life of the bulb and reduce energy consumption.

  • Medical X-ray Collimator Manual X-ray Collimator  SR102

    Medical X-ray Collimator Manual X-ray Collimator SR102

    Features
    Suitable for common X-ray diagnostic equipment with a tube voltage of 150kV
    The area projected by X-rays is rectangular.
    This product complies with relevant national and industry standards
    Small size
    Reliable performance, cost-effective.
    Using a single layer and two sets of lead leaves and a special internal protective structure to shield X-rays
    The adjustment of the irradiation field is manual, and the irradiation field is continuously adjustable
    The visible light field adopts high-brightness LED bulbs, which have a long service life
    The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
    The mechanical connection between this product and the X-ray tube is convenient and reliable, and the adjustment is easy