China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

We insist on offering premium quality manufacturing with superior business concept, honest product sales as well as finest and fast assistance. it will bring you not only the good quality product or service and huge profit, but the most significant is to occupy the endless market for Portable Xray Machine Amazon, Lead Glass Radiation Shielding, Target Of X Ray Tube, We welcome you to definitely stop by our manufacturing facility and sit up for creating pleasant organization relationships with clients in your own home and overseas while in the in the vicinity of long term.
China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray Detail:

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 85kV
Nominal Focal Spot 1.5(IEC60336/2005)
Filament Characteristics Ifmax=2.6A, Uf=3.0±0.5V
Nominal Input Power(at 1.0s) 1.8kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 10kJ
Target Angle 23°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx.120g

RT12-1.4-85

Cautions

Read the cautions before using the tube

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent life time
Certification:  SFDA


Product detail pictures:

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures


Related Product Guide:

abide by the contract, conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray , The product will supply to all over the world, such as: Haiti, Greece, belarus, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we'll continue to develop, to supply the high-quality goods and services, and promote lasting cooperation with our customers, common development and create a better future.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Lorraine from Malta - 2018.09.29 17:23
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Grace from Hamburg - 2017.09.29 11:19
    Write your message here and send it to us