Our mission is to become an innovative supplier of high-tech digital and communication devices by providing value added design, world-class manufacturing, and service capabilities for Varex Xray Tube, Roentgen X Ray Tube, Hand Switch X-Ray, We are looking forwards to establishing long-term business relationships with worldwide customers.
China wholesale X Ray Housing Factory - Dental X-ray Tube CEI Ox_70-m – Sailray Detail:

KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 70kV
Nominal Inverse Voltage 85kV
Nominal Focal Spot 0.8 (IEC60336/1993)
Max. Anode Heat content 7000J
Max. Current Continuous Service 2mA x 70kV
Max. Anode Cooling Rate 140W
Target Angle 19°
Filament Characteristics 1.8 – 2.2A, 2.4 – 3.3V
Permanent Filtration Min. 0.6mm Al / 50 kV(IEC60522/1999)
Target Material Tungsten
Nominal Anode Input Power 840W

details

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime

Prior to usage, season the tube in accordance with the seasoning schedule given below until the required tube voltage is attained. Example given – needs to revise by the manufacturer and specified in the data sheet of the part:

Initial incoming seasoning and seasoning schedule for idle period (more than6months)Circuit:

When the tube current is unstable in seasoning, immediately switch off the tube voltage and after an interval of 5 minutes or more, increase the tube voltage gradually from the low voltage while making sure that the tube current is stable. The withstand voltage performance of the tube unit will be lowered as the exposure time and the number of operation increase. Stain-like impact traces might appear on the x-ray tube target surface by slight discharge in the course of the seasoning. These phenomena are one process to recover the withstanding voltage performance at that time. Therefore, if it is in stable operation at the maximum tube voltage of seasoning subsequent to them, the tube unit can be used without any interference to its electrical performance which in use.

Cautions

Read the cautions before using the tube

 

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

 

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because  it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。


Product detail pictures:

China wholesale X Ray Housing Factory - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures

China wholesale X Ray Housing Factory - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures

China wholesale X Ray Housing Factory - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures


Related Product Guide:

To create much more benefit for consumers is our company philosophy; customer growing is our working chase for China wholesale X Ray Housing Factory - Dental X-ray Tube CEI Ox_70-m – Sailray , The product will supply to all over the world, such as: Iraq, Bogota, New Orleans, Thus far, our item associated with printer dtg a4 may be shown in most foreign nations as well as urban centers, which are sought after simply by targeted traffic. We all highly imagine that now we have now the full capacity to present you with contented merchandise. Desire to collect requests of your stuff and produce the long-term co-operation partnership. We very seriously promise:Csame top quality, better price; exact same selling price, higher quality.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Anne from Spain - 2018.06.19 10:42
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Eric from Australia - 2018.09.23 18:44
    Write your message here and send it to us