China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Copper X Ray Tube, Pediatric X Ray Tube, Modern Coolidge Tube, All products come with good quality and perfect after-sales services. Market-oriented and customer-oriented are what we have been being after. Sincerely look forward to Win-Win cooperation !
China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray Detail:

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 85kV
Nominal Focal Spot 1.5(IEC60336/2005)
Filament Characteristics Ifmax=2.6A, Uf=3.0±0.5V
Nominal Input Power(at 1.0s) 1.8kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 10kJ
Target Angle 23°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx.120g

RT12-1.4-85

Cautions

Read the cautions before using the tube

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent life time
Certification:  SFDA


Product detail pictures:

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray detail pictures


Related Product Guide:

Adhering into the theory of quality, services, efficiency and growth, now we have gained trusts and praises from domestic and international shopper for China wholesale X Ray Tube Explained Factory - Dental X-ray Tube Xd2 – Sailray , The product will supply to all over the world, such as: Slovakia, Greek, Rwanda, Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Samantha from Birmingham - 2018.06.05 13:10
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Hedda from Provence - 2017.04.08 14:55
    Write your message here and send it to us