OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

Quality first, Honesty as base, Sincere service and mutual profit is our idea, in order to develop continuously and pursue the excellence for William Coolidge X Ray Tube, Tube Head X Ray Machine, Type Of X Ray Tube, Customers' benefit and satisfaction are always our biggest goal. Please contact us. Give us a chance, give you a surprise.
OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray Detail:

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 85kV
Nominal Focal Spot 1.5(IEC60336/2005)
Filament Characteristics Ifmax=2.6A, Uf=3.0±0.5V
Nominal Input Power(at 1.0s) 1.8kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 10kJ
Target Angle 23°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx.120g

RT12-1.4-85

Cautions

Read the cautions before using the tube

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent life time
Certification:  SFDA


Product detail pictures:

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray detail pictures


Related Product Guide:

It adheres on the tenet Honest, industrious, enterprising, innovative to acquire new solutions continuously. It regards prospects, success as its personal success. Let us build prosperous future hand in hand for OEM High Quality Induction Motor X Ray Tube Manufacturer - Dental X-ray Tube Xd2 – Sailray , The product will supply to all over the world, such as: Burundi, Ottawa, Cairo, We have been in operation for more than 10 years. We are dedicated to quality products and consumer support. We currently own 27 product utility and design patents. We invite you to visit our company for a personalized tour and advanced business guidance.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By David from Finland - 2017.09.16 13:44
    The supplier abide the theory of quality the basic, trust the first and management the advanced so that they can ensure a reliable product quality and stable customers.
    5 Stars By Rigoberto Boler from Stuttgart - 2018.09.29 13:24
    Write your message here and send it to us